Pentair Pool heater ERR AGS Error Code
What the ERR AGS code means
On Pentair MasterTemp gas pool heaters, ERR AGS is automatic gas shutoff - water temperature after the second pass through the heat exchanger exceeded 140F. The front panel buttons are disabled and the heater is reset by cycling power.
Likely causes
- low water flow causing overheating
- failed automatic gas shutoff sensor/switch
- internal bypass fault
- restricted heat exchanger
How to fix it — step by step
- Turn power off to the heater and let the water cool
- Restore full flow - pump on, filter clean, valves fully open
- Cycle power to reset, as the panel buttons are disabled during this fault
- Restart once with proven good flow
- If ERR AGS returns, stop and call a pool/spa technician - this is a gas safety shutoff
Parts that commonly fix the ERR AGS code
- automatic gas shutoff switch - Shop at RepairClinic
- temperature sensor - Shop at RepairClinic
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.