Pentair Pool heater Display blank / will not turn on

What this problem usually means

A MasterTemp or UltraTemp with a blank display has lost its low-voltage supply, and the chain is short: line power in, a transformer stepping it down to 24 VAC, and the control circuitry that lights the display. The MasterTemp diagnostic flowcharts are built on exactly this walk — check for 24 VAC between the 24 VAC and GND terminals on the Ignition Control Module, verify the wiring between the module's 24 VAC and IND terminals and the Control Board, and replace the Control Board when the wiring is correct and the signal is absent. The heater's fault states (ERR AGS, ERR SFS and the rest) disable the front panel buttons and are reset by cycling power — but the display stays lit through all of them. A heater that is off, locked out, or slaved to an automation panel still shows something. Completely blank is always electrical: no line power, no 24 VAC, or a dead control board.

Likely causes

  1. No line power — breaker tripped, or the heater is fed through a timer/automation circuit that is off
  2. Transformer failed — line voltage in, no 24 VAC out to the control circuitry
  3. Loose, disconnected or rodent-damaged wiring between the Ignition Control Module and the Control Board
  4. Control Board failed (the verdict when 24 VAC and wiring check out and the display stays blank)
  5. Ignition Control Module failed

How to fix it — step by step

  1. Work the outside first: confirm the heater's breaker is on — turn it fully off, then back on, so a tripped breaker actually resets. If the heater is controlled by an automation panel, confirm the panel is in AUTO with heat enabled and a set temperature above the water temperature. And read the display one more time: any code or text at all (ERR codes, a temperature readout) means the heater has power and the fault is a different one; this is only for a display with nothing on it.
  2. Power-cycle once at the breaker — off for a full minute, then on. The lockout states (ERR AGS, ERR SFS) reset by cycling power; a display that returns was a latched control, not a dead one. A display that stays blank has a supply-side fault; continue.
  3. Kill power at the breaker before opening anything. With the control area open, do the visual pass: look for disconnected plugs and chewed or damaged wiring — rodent damage inside pool heaters is common enough to be a standing check — and reseat the connectors in the run between the Ignition Control Module and the Control Board, the exact wiring to verify.
  4. The meter walk that pinpoints it (yours if you are equipped, a technician's if not), following the flowchart: confirm line voltage arriving at the heater, then check for 24 VAC between the 24 VAC and GND terminals on the Ignition Control Module. Line voltage in and no 24 VAC means the transformer has failed — it is replaced as a part, and everything downstream of it is dark, which matches a blank display exactly. → Shop the ignition control module at Amazon → Shop the transformer at Amazon
  5. 24 VAC present at the module, wiring between the module and the Control Board verified correct, display still blank: replace the Control Board. That is the pinpoint — not a guess, the end of the decision tree. → Shop the control board at Amazon
  6. On an UltraTemp heat pump the same logic applies in the same order — line power, low-voltage supply, control board — with its fault codes likewise shown on a lit display; blank is electrical there too. Hand over in this form: breaker state, line voltage at the heater, 24 VAC present or absent at the module, and wiring state. Gas-side and board-replacement work is the technician's from here.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Parts run $15–$450

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related Pentair Pool heater problems

See all Pentair pool heater codes & guides →