Panasonic TV Viera plasma (2006-2010) 2 Blinks

What it should look like on your machine

then it repeats

2 blinks - then the pattern repeats. Count along with your machine and compare.

What this problem usually means

The red power LED blinks twice, pauses, and repeats: a 15V SOS - the 15V line is abnormal. Panasonic's GPH11 handbook names the trouble mode '15V down SOS' and lists the defective board as most often the P board, then A, SC and SS; the triggering conditions are missing P15V, a shorted P15V, or a wrong diagnostic by the D board. The set shuts down to protect the panel drive circuits.

Likely causes

  1. P board (power supply) not generating P15V
  2. Short circuit on the P15V line (SC or SS board load)
  3. Failed A board sending a false SOS diagnostic
  4. Aged capacitors on the power supply board

How to fix it — step by step

  1. Unplug the TV for at least 60 seconds, then plug back in and retry once to rule out a transient trip
  2. Access: unplug the TV, remove the back cover (the Service Hint diagram shows the cover screw positions), and wait 1 minute after power was off before removing any board — that is the stated wait for discharge from the electrolytic capacitors. Plasma drive boards work at panel voltages (Vsus is around 320V), so board handling and live tests are technician work.
  3. Where the boards are: P = power supply, A = the main board (DC-DC converter, speaker out/sound, AV terminals and switch, digital signal processor/microcomputer, HDMI interface, Peaks processor), D = format converter / Plasma AI / sub-field processor, SC = scan drive with SU = scan out (upper) and SD = scan out (lower) buffer boards plugged into it, SS = sustain drive. Each board is held by its connectors and mounting screws — for example the manual removes the P board by unlocking the cable clampers, disconnecting connectors P2, P6, P7, P9, P11, P12 and P25 and removing 10 screws; the A board unit by disconnecting A1, A7, A11, A12, A25, A51, A52 and the A20/A31/A32 flexible cables and removing 5 screws; the SC board (after removing SU and SD) via connector SC2, flexible cable SC20 and 6 screws; the SS board via SS11, SS12, SS23, jumper SS34 (kept for the new board), flexible cables SS53A/SS56A and 5 screws.
  4. Have a technician measure P15V at the P board output: no voltage points to the P board; voltage present at the output but the SOS still trips points to a shorted load on an SC/SS board or a false diagnostic from the A/D side — the load is isolated by disconnecting loads one at a time. → Shop the power supply board (p board) at Amazon
  5. Replace the power supply (P) board with one matched to your exact model number if it is not generating P15V; if the P board tests good, the A board or a shorted SC/SS board is next in Panasonic's suspect order.
  6. Replacement pattern for the condemned board: photograph and note every connector first, unlock the cable clampers, disconnect the board's connectors and flexible cables, remove its mounting screws, fit the replacement matched to the exact model and panel size, reconnect in the original positions, refit the back cover, and confirm the blink pattern is gone and the set runs. After a board exchange the driver voltage checks (Vsus, Vad, Ve against the panel label) — a technician step.
  7. Tell the technician: the exact model number, the blink/LED pattern you counted, what you already tried (power reset, direct wall outlet, devices disconnected), and which board the tests above condemned — that saves a repeat diagnosis visit.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Parts run $80–$300Typical pro repair $200–$500
  • power supply board (P board)$80–$300Shop at Amazon
  • main board (A board)$80–$300Shop at Amazon
  • Tools for this job, if you need them$10–$40

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.