LiftMaster Security+ 2.0 / 3.0 Error Codes
Find your code in the list below. Each page explains what the code means, the most likely causes, step-by-step fixes you can do yourself, and the parts that commonly resolve it. 14 codes covered.
Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.
| Code | What it means | Check first | |
|---|---|---|---|
| 1-1 | Code 1-1 (1 UP flash, 1 DOWN flash): the safety sensors are blocked, misaligned, disconnected, or a sensor… | Something physically blocking the beam between the sensors | › |
| 1-2 | Code 1-2 (1 UP flash, 2 DOWN flashes): the safety sensor wires are reversed or shorted. Unlike 1-1, the door… | Sensor wires reversed at the sensors or at the opener (white and striped swapped) | › |
| 1-5 | Code 1-5 (1 UP flash, 5 DOWN flashes): RPM not detected - the opener commanded the motor but did not sense it… | Door mechanically stopped: binding, a manual lock engaged, or a broken spring making | › |
| 1-6 | Code 1-6 (1 UP flash, 6 DOWN flashes): unexpected door movement - the opener detected the door moving without… | Out-of-balance door - worn or incorrect springs no longer counterbalancing the door's | › |
| 2-1 | Code 2-1 (2 UP flashes, 1 DOWN): a logic board component failure. The logic board - the opener's main circuit… | A failed component on the logic board | › |
| 2-2 | Code 2-2 (2 UP flashes, 2 DOWN): a logic board component failure. The logic board - the opener's main circuit… | A failed component on the logic board | › |
| 2-3 | Code 2-3 (2 UP flashes, 3 DOWN): a logic board component failure. The logic board - the opener's main circuit… | A failed component on the logic board | › |
| 2-4 | Code 2-4 (2 UP flashes, 4 DOWN): a logic board component failure. The logic board - the opener's main circuit… | A failed component on the logic board | › |
| 2-5 | Code 2-5 (2 UP flashes, 5 DOWN): a logic board component failure. The logic board - the opener's main circuit… | A failed component on the logic board | › |
| 4-1 | Code 4-1 (4 UP flashes, 1 DOWN): resistance while closing. The opener sensed an unexpected change in motor… | An object in the door's path or in a track | › |
| 4-2 | Code 4-2 (4 UP flashes, 2 DOWN flashes): resistance while opening. The door stops before it is fully open… | Obstruction in the door path or tracks | › |
| 4-3 | Code 4-3 (4 UP flashes, 3 DOWN flashes): RPM lost while closing. The door starts down, then stops and… | Debris or an object low in the tracks or at the floor line | › |
| 4-4 | Code 4-4 (4 UP flashes, 4 DOWN flashes): RPM lost while opening. The door stops before it is fully open… | Obstruction or binding in the tracks or door hardware | › |
| 4-5 | Code 4-5 (4 UP flashes, 5 DOWN flashes): unrecognized travel module. The opener does not recognize the travel… | Wrong travel module installed for the opener model | › |
All LiftMaster garage door opener models & codes →
Looking for a part?
Once you know the part you need, browse LiftMaster Security+ 2.0 / 3.0 replacement parts → The parts shelves are organized by brand, with the parts that actually fix these codes.