Jacuzzi Hot tub SN--2 Error Code
What the SN--2 code means
On Jacuzzi J-300 Collection hot tubs, SN--2 (WATER SENSOR ERROR) means the main water temperature sensor is not functioning, open or shorted, and the heater is disabled.
Likely causes
- open temperature sensor
- shorted temperature sensor
- damaged sensor wiring
How to fix it — step by step
- Turn power off at the breaker and leave the spa off
- Do not use the spa while this code is showing
- Contact your Jacuzzi dealer or a qualified spa technician - the manual requires dealer repair for this fault
Parts that commonly fix the SN--2 code
- temperature sensor - Shop at RepairClinic
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.