What this problem usually means

An InSinkErator that will not run at all — silent when the switch is flipped — has very often simply tripped its overload protector: a small square red button on the bottom of the unit that drops down about a quarter of an inch (5mm) when it trips, cutting the motor off to protect it, usually after a jam or a heavy load. Checking that button is part of the standard recovery: gently press it back in, and if it does not stay up, wait ten minutes for the motor to cool and try again. Note the brand split: EZ Connect units and some newer models use an automatic overload switch instead — those recover by cooling with the switch off (up to 20 minutes), with no button to press.

Likely causes

  1. Overload protector tripped after a jam or heavy load, cutting power to the motor (most common)
  2. Motor still too hot, so the protector will not stay reset yet
  3. Tripped circuit breaker or blown fuse at the service panel (InSinkErator's next check if the motor remains inoperative)
  4. An uncleared jam still in the grinding chamber, re-tripping the protector

How to fix it — step by step

  1. Make certain the disposal's switch is in the off position before you start — InSinkErator's standing instruction — and never place your hand in the disposal at any time
  2. Get under the sink and find the overload protector on the bottom of the unit, facing the floor: a small square red button. If it has tripped you will see it dropped down about a quarter of an inch (5mm) — that dropped button is the diagnosis
  3. Gently press the red button back in. If it stays up, the protector is reset. If it does not stay up, wait ten minutes and try again — a hot motor holds the protector open, and the wait is part of the procedure, not a failure
  4. On units with an automatic overload switch (InSinkErator's EZ Connect procedure), there is no button: leave the wall switch off (or unplug an air-switch unit) and allow the disposal to cool for up to 20 minutes before turning it back on
  5. Before running it, shine a flashlight into the grinding chamber and remove any object you see with tongs or pliers — a jam left in the chamber will trip the protector again immediately
  6. Turn on the water, then the disposal: it should run. If the motor remains inoperative after reset and cooling, InSinkErator's next check is the service panel for tripped circuit breakers or blown fuses

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

This fault usually does not need a replacement part - the fix is in the steps above. If your plumbing does need a part, start with the link above.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manufacturer documentation

Manual & model number

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related InSinkErator Plumbing problems

See all InSinkErator plumbing codes & guides →