What this problem usually means

The brush roll (agitator) does not turn, so carpet is not being agitated. On WindTunnels the roll is belt-driven — and on self-propelled models there are two belts with different jobs.

Likely causes

  1. Belt is broken — belts snap when the brush jams on debris or something sharp is picked up
  2. Belt is stretched with age and slips (change the belt about once a year)
  3. Brush roll is jammed — Hoover fits an automatic brushroll shutoff that stops the roll on overload or jam
  4. On self-propelled models: the flat motor-pulley belt has failed, or the smaller agitator V-belt has come out of its groove

How to fix it — step by step

  1. First, the jam check — it costs nothing: Hoover fits an automatic brushroll shutoff that stops the roll if it jams. Turn the cleaner over, clear any obstruction out of the brush roll area, and resume cleaning — a roll that restarts was shut off by a jam, not a broken belt.
  2. If it still does not turn, open the base: unplug, undo the screws at the rear of the base next to the wheels (2 screws on many models, 4 on some), lift off the height adjuster knob and hose, and lift the hood off. The belt and brush roll are now exposed.
  3. Inspect the belt: snapped or hanging loose means replace it; intact but slack and glossy means it has stretched and slips under load — also replace it. Fit the new belt over the motor spindle, seat it on the brush roll, and rotate the roll by hand to check the belt tracks and turns freely before refitting the hood, hose and height adjuster. → Shop the brush roll at Amazon
  4. Self-propelled models have a second belt, and The two belts are separate: under the base plate (Phillips screws) the wider flat belt runs from the small metal motor shaft to the large pulley and drives the self-propel; the smaller agitator V-belt runs from the inside of the large pulley to the groove in the brush roll. Hand test: move the brush roll by hand — both belts should move. The flat motor-pulley belt is the one that most likely needs replacing; the agitator belt is expected to last the life of the vacuum but can be replaced if broken or loose enough to fall out of its groove (take the motor-pulley belt off first to reach it).
  5. Refit everything, plug in and test on carpet. A roll that turns under load confirms the fix. A new belt that comes off again straight away means the brush roll ends or pulley are fouled or damaged — clean and inspect them before fitting another belt.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Parts run $5–$50

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manufacturer documentation

Manual & model number

Find your model number on the back of the machine or the underside of the base. It's the key to the right manual pages and the right parts.

Related Hoover Upright vacuum WindTunnel problems

See all Hoover WindTunnel codes & guides →