Generac Generator GP Series Portable Generators Starts Then Stops
What this problem usually means
The engine starts and then shuts down during operation, or starts and shuts off right away. The panel badge light is the key read: a red blinking light on the side panel badge is a COsense shutoff from accumulating carbon monoxide, a yellow blinking light is a COsense system fault. Without a badge light, the causes are fuel and oil.
Likely causes
- Out of fuel
- Low oil level
- COsense shutoff from accumulating carbon monoxide, red light blinking on the side panel badge
- COsense shutoff from a system fault, yellow light blinking on the side panel badge
- Fault in the engine
How to fix it — step by step
- Read the side panel badge before restarting and write down the colour. Red and yellow lead to different fixes, and restarting blind erases the evidence.
- Red light: relocate the generator to an open area outside, far away from windows, doors and vents, following all safety instructions, and restart there. A generator that then runs continuously was shut down by its own accumulating exhaust, and the new location is the fix.
- Yellow light: restart once and confirm the yellow light blinks when the generator shuts off. If COsense continues to sense the fault and shut off, the pinpoint is the COsense system: contact an Independent Authorized Service Dealer.
- No badge light: check fuel and refill the tank, or replace the LP cylinder on dual fuel use. Then check oil on level ground and fill the crankcase to the correct level. One of the two found low and corrected, with the engine then staying running, is the explanation.
- If fuel and oil are both correct, there is no badge light, and it still shuts down, Generac's remaining cause is a fault in the engine. That is dealer work, with the badge-light observation reported exactly as seen.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
Then the fault is internal - there is no documented owner fix beyond the steps above. If you're not comfortable taking it apart yourself, a repair shop is the next step.
Parts that commonly fix it
This fault usually does not need a replacement part - the fix is in the steps above. If your generator does need a part, start with the link above.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.
Related Generac Generator GP Series Portable Generators problems
- Surges or Stumbles
- Won't Start
- Bogs Under Load
- Electric Start Won't Crank
- Low Oil Level Shutdown
- No Power Output
See all Generac GP Series Portable Generators codes & guides →