GE Dryer E3 Error Code
What the E3 code means
On GE Profile DPVH890 dryers (technical service manual): Outlet Short - the outlet thermistor is shorted; check and replace if necessary.
Likely causes
- Shorted outlet thermistor
- Pinched or damaged thermistor wiring
- Connector contamination
How to fix it — step by step
- Unplug the dryer and let it cool
- Clean the lint filter and clear any vent restriction before retrying
- Try one cycle; if E3 returns, the thermistor needs professional testing/replacement
Parts that commonly fix the E3 code
- outlet thermistor - Shop at RepairClinic
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.