What this problem usually means

Three chirps every minute, with the Power/Smoke LED flashing about three times once a minute, is the malfunction signal on the SC7010B. The alarm has detected an internal fault. Do not confuse it with this model's low-battery warning, which is a single chirp once a minute.

Likely causes

  1. An internal malfunction in the alarm

How to fix it — step by step

  1. Confirm the signal at the unit: count the chirps over a full minute — three chirps every minute, with the Power/Smoke LED flashing about three times once a minute, is the SC7010B malfunction signal per its signal table. One chirp a minute would be low battery instead; the counts are the test, so count before acting.
  2. Understand the access: the SC7010B is a hardwired alarm on a ceiling or wall mounting bracket with a battery in a side-load drawer. A malfunction is internal — there is no user repair and no battery change that clears it, so do not keep swapping the backup battery hoping the three chirps stop.
  3. Replace the alarm: turn off power to the alarm circuit at the breaker first (the electrical-shock warning for removing this unit), twist the alarm off its mounting bracket, unplug the power connector from the back, then connect and mount the replacement and restore power.
  4. Verify the fix: press and hold the new alarm's Test/Silence button until it alarms — a unit that sounds on test and then sits silent, with no three-chirp cycle over the following minutes, has cleared the fault. A replacement that also chirps three times a minute points back at the wiring or power supply, not a second bad alarm — have the circuit checked.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Parts run $35–$100

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related First Alert Smoke & co alarm SC7010B problems

See all First Alert SC7010B codes & guides →