Emerson Thermostat Call for Service
What this problem usually means
On a Sensi thermostat, a 'Call for Service' display without E5 means, per Copeland/Sensi, that 'your heating/cooling system is likely not responding as it should.' Sensi's article splits it by pattern: the thermostat displays 'heating' but room temperature is dropping, or displays 'cooling' but room temperature is rising; it also covers being unable to switch modes, a temperature reading of 99°F+ / '--' or humidity of 255% (an internal sensor problem — contact Sensi support for a replacement), and one wiring cause an owner can check: voltage on a wire landed in the 'L' diagnostic terminal will itself display 'Call for Service,' and the L wire is not needed for normal operation.
Likely causes
- Heating system not responding while the thermostat displays 'heating' (room temperature dropping)
- Cooling system not responding while the thermostat displays 'cooling' (room temperature rising)
- Voltage present on a wire connected to the 'L' diagnostic terminal — Sensi's published wiring cause
- Internal sensor failure, if the reading is 99°F+, '--' for temperature, or 255% for humidity
How to fix it — step by step
- Read the pattern first: is it calling for heat while the room cools, or calling for cool while the room warms? Follow the matching Sensi troubleshooting (Why isn't my heating/cooling turning on; Loss of heating/cooling alert) to separate a settings/power cause from an equipment cause before assuming a failure
- Turn power to the HVAC system OFF at the breaker or furnace switch before you pull the thermostat off its wall plate or touch any wiring — that is the makers' own warning on this work.
- Check the L terminal: with power off, remove the thermostat cover and see whether a wire is landed in 'L'. If there is, Sensi's own test is to remove it, push it back into the wall, reinstall the thermostat and restore power — if 'Call for Service' disappears, voltage on that diagnostic wire was the cause. Sensi adds you may want a service professional to explain why voltage is present on the diagnostic wire, even if the system now runs normally
- Check the sensor branch: if the room temperature reads 99°F or higher, shows '--', or humidity reads 255%, Sensi identifies an internal sensor problem — contact Sensi support for a replacement thermostat rather than troubleshooting the HVAC system
- If there is no L wire, the sensor readings are sane, and the system genuinely does not respond to a proven call, the pinpoint is the heating/cooling equipment — contact an HVAC professional, per Sensi, and report the 'Call for Service' display and the pattern you observed
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Thermostat.
Parts that commonly fix it
- Thermostat$70–$280Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.