Delta Plumbing Fill valve won't shut off
What this problem usually means
A Delta toilet keeps running from the top of the tank when the fill valve does not shut off: the float is set too high, so the water level rises above the overflow tube and the tank continuously drains into it, or the valve itself has failed even at a correct setting. Delta's guide sequences the fix — test and adjust the float first (the water should stop one-half to 1 inch below the top of the overflow tube), and only replace the fill valve if the water is still running after the float is adjusted.
Likely causes
- Float set too high, so water rises above the overflow tube and drains continuously (most common)
- Float sticking or not rising freely with the water
- Fill valve failed and no longer shutting off even at a correct float setting
How to fix it — step by step
- Take the tank lid off and flush, then watch where the water stops. Delta's benchmark: the level should stop one-half to 1 inch below the top of the overflow tube. Water that stops higher, or keeps spilling into the tube, proves the float/fill valve side is at fault
- Adjust the float down: bend down the arm or rod connecting the float to the valve, or turn the small screws on top of the valve. Lowering the float makes the valve turn off sooner
- Flush and re-check the stopping level. If the water now stops in the one-half to 1 inch band below the overflow top and the toilet goes silent, the float setting was the whole fault
- If the water is still running after the float adjustment, replace the fill valve: turn the water off at the shut-off valve behind the tank, flush to drain the tank, disconnect the water supply line and unscrew the lock nut from outside the tank, and remove the old valve
- Install the replacement valve per its package directions, adjust its float to the same correct water level, turn the water on, and confirm two silent, correctly-levelled refills in a row → Shop the fill valve at Amazon
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
Then the likely broken part is the fill valve.
Parts that commonly fix it
- fill valve$10–$20Shop at Amazon
- Tools for this job, if you need them$10–$40
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.