What this problem usually means

The door will not close and the light bulbs blink on the motor unit. The cause: the safety reversing sensor must be connected and aligned correctly before the opener will move in the down direction.

Likely causes

  1. Safety reversing sensors not connected
  2. Safety reversing sensors misaligned or obstructed

How to fix it — step by step

  1. Look at the two sensor eyes at the bottom of the tracks — external, none needed beyond a cloth. Verify they are installed, facing each other and free of obstructions; wipe the lenses
  2. Read the indicator lights: the sending eye (amber) and receiving eye (green) should both glow steady. A dark or flashing receiving eye means the beam is not being received — realign until it holds steady
  3. Count the diagnostic LED flashes on the motor unit and match them to the chart: 1 flash = sensor wire open, 2 = wire shorted or reversed, 4 = sensors slightly misaligned. Fix the branch the count names, then retest a close
  4. If both sensor lights are steady, the path is clear and the door still will not close, the remaining suspects are the sensor wiring back to the motor unit or the sensors themselves — that is the pinpoint to hand over

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Parts run $10–$60Typical pro repair $150–$250Fixing it yourself typically saves $90–$240

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related Craftsman Garage door opener 139.53915D problems

See all Craftsman 139.53915D codes & guides →