What the 138 code means

A system malfunction (the control's most serious fault class): high-capacity compressor lockout. The Evolution Connex wall control displays fault 138 as "THERMAL LOCKOUT IN HIGH STAGE". The two-stage outdoor unit's compressor overheated while running in high stage and its thermal cutout tripped, so the system locked the compressor out to protect it. The fault is generated by the outdoor unit but is reported on - and read from - the wall control, which is why it never appears on the furnace's own code list.

Likely causes

  1. Repeated high-capacity thermal cutout trips - fault 138 is the lockout that follows the high-stage thermal cutout events (fault 135) in the same fault table
  2. Internal compressor overload in high stage - the cutout is the compressor's own over-temperature protection
  3. Start relay failing to release - the cause Carrier's table names for the high-capacity thermal cutout

How to fix it — step by step

  1. Note what the wall control shows: fault 138, "THERMAL LOCKOUT IN HIGH STAGE" - the system may still run in low stage, but high stage is locked out
  2. Check the indoor filter and replace it if it is clogged - restricted airflow anywhere in the system raises compressor temperatures
  3. Outside, look at the outdoor unit: clear leaves and debris away from it and check the coil faces are not matted with dirt (external check only - do not open the unit)
  4. Turn power to the system off at the breaker or outdoor disconnect for at least 5 minutes, then restore it once and watch whether fault 138 returns
  5. If 138 comes back, stop resetting it: a repeat thermal lockout means the compressor is still overheating - refrigerant charge, the start relay and the compressor itself are sealed-system work for a technician

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 138 code

No specific replacement part is documented for this fault. If the checks above do not clear it, your thermostat likely needs to be disassembled and an internal part replaced - and since the manufacturer publishes no procedure for that, it is the point where most owners hand it to a repair shop.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Working on a specific model? The official Bryant manual is on Bryant's support site — you'll need your model number.

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related Bryant Thermostat Evolution Connex Control error codes

See all Bryant Evolution Connex Control codes & guides →